home *** CD-ROM | disk | FTP | other *** search
/ Spec Disk 1998 Spring 4.0 / Spec Disk 1998 Spring 4.0.iso / text / 08565ctd.txt < prev    next >
Text File  |  1998-06-10  |  67KB  |  1,471 lines

  1.                          SECTION 08565
  2.  
  3.                       VINYL (PVC) WINDOWS
  4. NOTE ** CertainTeed Corporation vinyl windows, patio doors,
  5.         and specialty windows.
  6. NOTE **
  7. NOTE ** This section is based on fenestration products
  8.         manufactured by CertainTeed Corporation, Vinyl
  9.         Building Products Group, which is located at the
  10.         following address:
  11. NOTE **    750 E. Swedesford Road
  12. NOTE **    P.O. Box 860
  13. NOTE **    Valley Forge, PA 19482
  14. NOTE **    Tel:  (800) 233-8990
  15. NOTE **
  16. NOTE ** CertainTeed Corporation's product lines of New
  17.         Castle(tm) windows and doors, New Castle(tm) XT
  18.         windows, and CertainTeed Garden Window offer a full
  19.         selection of vinyl windows, patio doors, and
  20.         specialty windows for installation in new
  21.         residential and light commercial or institutional
  22.         structures.
  23. NOTE **
  24. NOTE ** SECTION 08565 - VINYL (PVC) WINDOWS, Copyright
  25.         1997, The Architect's Catalog, Inc.
  26.  
  27.  
  28. PART 1  GENERAL
  29.  
  30. 1.1 SECTION INCLUDES
  31. NOTE ** Delete items below not required for project.
  32.  
  33.     A.  Single Hung Windows.
  34.  
  35.     B.  Double Hung Windows.
  36.  
  37.     C.  Horizontal Gliding Windows.
  38.  
  39.     D.  Casement Windows.
  40.  
  41.     E.  Awning Windows.
  42.  
  43.     F.  Bow Windows.
  44.  
  45.     G.  Bay Windows.
  46.  
  47.     H.  Operable Extended Arch Windows.
  48.  
  49.     I.  Fixed Geometric Windows.
  50.  
  51.     J.  Fixed Windows and Transoms.
  52.  
  53.     K.  Patio Doors.
  54.  
  55.     L.  Garden Windows.
  56.  
  57. 1.2 RELATED SECTIONS
  58. NOTE ** Delete any sections below not relevant to this
  59.         project; add others as required.
  60.  
  61.     Section 05400 - Cold Formed Metal Framing.
  62.  
  63.     Section 06100 - Rough Carpentry.
  64.  
  65.     Section 09111 - Non-Load-Bearing Metal Framing.
  66.  
  67. 1.3 REFERENCES
  68. NOTE ** Delete references from the list below that are not
  69.         actually required by the text of the edited
  70.         section.
  71.  
  72.     A.  AAMA 101 - Voluntary Specification for Aluminum and
  73.         Polyvinyl Chloride (PVC) Prime Windows and Glass Doors.
  74.  
  75.     B.  AAMA 303 - Voluntary Specification for Poly (Vinyl
  76.         Chloride) (PVC) Exterior Profile Extrusions.
  77.  
  78.     C.  AAMA 701 - Voluntary Specification for Pile Weatherstrip.
  79.  
  80.     D.  AAMA 902 - Voluntary Specification for Sash Balances.
  81.  
  82.     E.  ALI - Certification Program for Sealed Insulating Glass
  83.         Units, SIG-901; Associated Laboratories, Inc.
  84.  
  85.     F.  ASCE 7 - Minimum Design Loads for Buildings and other
  86.         Structures.
  87.  
  88.     G.  ASI B18-6-4 - Specification for Screw Fasteners; American
  89.         Standards Institute.
  90.  
  91.     H.  ASTM D 635 - Standard Test Method for Rate of Burning
  92.         and/or Extent and Time of Burning of Self-Supporting
  93.         Plastics in a Horizontal Position.
  94.  
  95.     I.  ASTM D 1929 - Standard Test Method for Ignition
  96.         Properties of Plastics.
  97.  
  98.     J.  ASTM D 4726 - Standard Specification for White Rigid
  99.         PolyVinyl Chloride (PVC) Exterior Profile Extrusions Used
  100.         for Assembled Windows and Doors.
  101.  
  102.     K.  ASTM E 774 - Standard Specification for Sealed Insulating
  103.         Glass Units.
  104.  
  105.     L.  CAWM 301 - Forced Entry Testing; California Association
  106.         of Window Manufacturers.
  107.  
  108.     M.  IGCC - Classification of Insulating Glass Units;
  109.         Insulating Glass Certification Council.
  110.  
  111.     N.  NFRC 100 (5M) - Thermal Properties; National Fenestration
  112.         Rating Council.
  113.  
  114. 1.4 SUBMITTALS
  115.  
  116.     A.  Submit under provisions of Section 01300.
  117.  
  118.     B.  Product Data:  Provide manufacturer's standard details
  119.         and catalog data demonstrating compliance with referenced
  120.         standards; include installation instructions and storage
  121.         requirements.
  122.  
  123.     C.  Shop Drawings:  Submit for approval the following:
  124.         Elevation for each style window and door specified;
  125.             indicate sizes, glazing types, muntin types and
  126.             designs.
  127.         Schedule:  Indicate each window and door in project;
  128.             reference each unit to specific elevation style.
  129.         Details:  Head, jamb, and sill details for each project
  130.             condition.
  131.  
  132.     D.  Selection Samples:  Manufacturer's full range of
  133.         available colors.
  134.  
  135.     E.  Verification Samples:  Operating units of each style
  136.         window and door specified; verification samples may be
  137.         operating scaled-down mock-ups of actual-size units.
  138.         Verification samples will be returned to manufacturer's
  139.         representative at project closeout.
  140.  
  141.     F.  Quality Assurance Submittals:  Evidence of certifications
  142.         of window units required in QUALITY ASSURANCE Article of
  143.         this section.
  144.  
  145. 1.5 QUALITY ASSURANCE
  146.  
  147.     A.  Qualifications:
  148.         1.  Manufacturer:  Minimum three years documented
  149.             experience producing products specified in this
  150.             section.
  151.         2.  Installer:  Minimum three years documented experience
  152.             installing products specified in this section.
  153.  
  154.     B.  Certifications:  Provide window units independently
  155.         tested and certified for air infiltration, water
  156.         penetration, and structural performance by AAMA, for
  157.         thermal transmission and solar heat gain performance by
  158.         NFRC, and insulating glass certified by ALI/IGCC, to ASTM
  159.         E 774, Class CBA.
  160.  
  161. 1.6 DELIVERY, STORAGE, AND HANDLING
  162.  
  163.     A.  Protect products from moisture, construction traffic, and
  164.         damage in accord with manufacturer's instructions.
  165.  
  166.     B.  Do not use non-vented plastic or canvas shelters; provide
  167.         1/4-inch (6.3 mm) space between units to promote air
  168.         circulation.
  169.  
  170. 1.7 WARRANTY
  171.  
  172.     A.  Manufacturer's Warranty:  Furnish manufacturer's Lifetime
  173.         Limited Warranty on window products, including five year
  174.         SureStart Protection, transferable to subsequent owners.
  175.  
  176.  
  177. PART 2  PRODUCTS
  178.  
  179. 2.1 MANUFACTURERS
  180.  
  181.     A.  Acceptable Manufacturer:  CertainTeed Corporation, Vinyl
  182.         Building Products Group, or any of its licensed regional
  183.         fabricators; 750 E. Swedesford Road, P.O. Box 860, Valley
  184.         Forge, PA 19482; ASD. Tel. (800) 233-8990.
  185. NOTE ** Delete one of the two paragraphs below; coordinate
  186.         with Division 1 requirements.
  187.  
  188.     B.  Requests for substitutions will be considered in
  189.         accordance with provisions of Section 01600.
  190.  
  191.     C.  Substitutions:  Not permitted.
  192.  
  193. 2.2 COMPONENTS
  194.  
  195.     A.  Window Frame and Sash Members:  Impact resistant,
  196.         exterior grade polyvinyl chloride extrusions complying
  197.         with AAMA 303 and ASTM D 4726.
  198.         1.  Ignition temperature, when tested in accordance with
  199.             ASTM D 1929:  Minimum of 824 degrees F (440 degrees
  200.             C).
  201.         2.  Flammability, when tested in accordance with ASTM D
  202.             635:  Burn time of less than 5 seconds and burn
  203.             distance of less than 10 mm.
  204.         3.  Non-corroding, non-flaking, non-chipping, non-
  205.             rotting; no electrical conductance; low thermal
  206.             conductance
  207.         4.  Minimum external wall thickness:  0.070 inch (1.8 mm)
  208.             nominal.
  209.         5.  Finish of sight-exposed surfaces:  Smooth gloss
  210.             finish with uniform consistent color.
  211. NOTE ** Standard factory glazing for New Castle single-
  212.         hung, gliding, fixed and Architectural Shape window
  213.         units is 5/8 inch (16 mm) insulating unit with 3/32
  214.         inch (2.5 mm) thick or 1/8 inch (3 mm) thick clear
  215.         inner pane and outer pane (depending on window unit
  216.         size and specified AAMA 101 grade requirements),
  217.         with hermetically sealed air space and low-
  218.         conductance spacer.
  219. NOTE **
  220. NOTE ** Standard factory glazing for New Castle casement,
  221.         fixed casement, and awning window units is 7/8 inch
  222.         (22 mm) insulating unit with 3/32 inch (2.5 mm)
  223.         thick or 1/8 inch (3 mm) thick clear inner pane and
  224.         outer pane (depending on window unit size and
  225.         specified AAMA 101 grade requirements), with
  226.         hermetically sealed air space and low-conductance
  227.         spacer.
  228. NOTE ** Standard factory glazing for New Castle XT double-
  229.         hung, double-gliding, fixed, and Architectural
  230.         Shape window units is 7/8 inch (22 mm) insulating
  231.         unit with 3/32 inch (2.5 mm) thick or 1/8 inch (3
  232.         mm) thick clear inner pane and outer pane
  233.         (depending on window unit size and specified AAMA
  234.         101 grade requirements), with hermetically sealed
  235.         air space and low-conductance spacer.
  236. NOTE **
  237. NOTE ** Despite the fact that standard factory glazing is
  238.         as indicated above, window size and local codes may
  239.         require specifying one of the following glass
  240.         thickness (strength) options:
  241. NOTE **
  242. NOTE ** Increased thickness to 1/8 inch (3 mm), 5/32 inch
  243.         (4 mm), or 3/16 inch (5 mm).
  244. NOTE ** Heat-strengthened or tempered glass.
  245. NOTE ** If more than one type of insulating glass unit is
  246.         required for project, copy paragraph below,
  247.         designate unit styles, coordinate with drawings,
  248.         schedule article, and window style article.
  249. NOTE **
  250. NOTE ** Edit paragraph below for specified requirements.
  251. NOTE **
  252. NOTE ** Glass color options are:  Clear, green, bronze,
  253.         blue, grey, obscure.  Other colors may be
  254.         available.
  255.  
  256.     B.  Insulating Unit Type __:  Complying with ASTM E 774,
  257.         Class CBA; unit thickness ___ inch (___ mm):
  258.         1.  Outer Pane:  ____ inch (___ mm) thick glass, clear
  259.             color.
  260. NOTE ** Delete the following paragraph if low-emissivity
  261.         coating is not required.
  262.         2.  Outer Pane Coating:   Thermaflect(R) double sputter-
  263.             coat high-performance low-emissivity softcoat on air
  264.             chamber side of pane.
  265. NOTE ** Delete one of the following two paragraphs, to
  266.         specify air space filled with plain air or with
  267.         Argon gas.
  268.         3.  Air Chamber:  Hermetically sealed space between
  269.             panes, low-conductance spacer, desiccated butyl or
  270.             polyisobutylene chamber sealant.
  271.         4.  Air Chamber:  Hermetically sealed space between
  272.             panes, low-conductance spacer, desiccated butyl or
  273.             polyisobutylene chamber sealant, Argon gas filled to
  274.             minimum 97 percent initial fill.
  275.         5.  Inner Pane:  ____ inch (___ mm) thick glass, clear
  276.             color.
  277. NOTE ** Consult manufacturer's product data for thermal
  278.         performance of window styles and glazing options;
  279.         coordinate with window styles and glazing
  280.         selections.
  281.         6.  Thermal Performance:
  282.             a.  Total Unit U-Value:  ____ (__ metric equivalent).
  283.             b.  Daylight Transmittance:  ____ percent.
  284.             c.  Ultraviolet Block:  ____.
  285.             d.  Shading Coefficient:  ____.
  286.  
  287.     C.  Screens:  Type installable from interior side, providing
  288.         only reasonable insect control when operable sash is in
  289.         open position; re-wirable glass fiber mesh, 14 x 18 mesh,
  290.         secured in channel of aluminum box frame with continuous
  291.         vinyl spline; frame color matching frame and sash
  292.         interior color.
  293.  
  294.     D.  Operating Hardware:  Types for specified operable-sash
  295.         windows; sight-exposed hardware of UV-stabilized
  296.         engineered polycarbonate plastic, color matched to vinyl
  297.         extrusions for uniform appearance.
  298.  
  299.     E.  Fasteners:  Corrosion-resistant, and conforming to ASI
  300.         B18-6-4.
  301.  
  302.     F.  Weatherstripping:  Types for specified operable-sash
  303.         windows and operable doors.
  304. NOTE ** Delete or retain one or both paragraphs below for
  305.         specified window units.
  306.  
  307.     G.  Integral Muntins:  Aluminum, pre-finished to match window
  308.         frame, factory-mounted between panes of insulating glass
  309.         unit before sealing glass unit.
  310.  
  311.     H.  Applied Muntins:  Polyvinyl chloride (PVC), color
  312.         matching window frame, applied to interior side of window
  313.         using proprietary attachment system.
  314.  
  315. 2.3 SINGLE HUNG WINDOWS
  316.  
  317.     A.  Acceptable Product:  New Castle Single-Hung.
  318. NOTE ** Consult manufacturer's product data for performance
  319.         of window styles; coordinate with window
  320.         selections.
  321.         1.  Unit performance when tested in accordance with AAMA
  322.             101:
  323.             a.  Air Infiltration:  ____ cubic feet per minute (__
  324.                 cu m/hr).
  325.             b.  Water Penetration: ____ cubic feet per minute (__
  326.                 cu m/hr).
  327.             c.  Structural Performance:  ____ pounds per square
  328.                 foot (__ kPa).
  329.             d.  Overall Rating:  Grade __.
  330.             e.  Operating Force:  ____ pounds (__ kg).
  331.         2.  Frame and Sash Construction:  Mitered and fusion-
  332.             welded corners; integral 1 inch (25.4 mm) pre-punched
  333.             nailing fin four sides; integral weep system; tilt-in
  334.             lower sash interlocking to stay bar, with surface-
  335.             mounted tilt latches and molded-in lift rail; one
  336.             operable lower sash, one upper fixed sash.
  337.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  338.         4.  Operating Hardware:
  339.             a.  Locks:  Cam-type sash lock and keeper meeting
  340.                 forced entry resistance requirements of CAWM 301,
  341.                 engineered to force meeting rails together, for
  342.                 minimum air infiltration.
  343.             b.  Balances:  Stainless steel constant-force spring
  344.                 balances, 3/4 inch (19 mm) wide, meeting AAMA
  345.                 902, providing maintenance free operation without
  346.                 post-installation adjustment or lubrication.
  347.         5.  Weatherstripping:  Double-row high-density silicone-
  348.             treated polypropylene pile, with double mylar fin,
  349.             meeting AAMA 701; compression-type bulb seal at lower
  350.             rail meeting sill.
  351.         6.  Screens:  Frame color matching window frame and sash
  352.             interior color.
  353. NOTE ** Retain one or delete both paragraphs below for
  354.         specified window units.
  355.         7.  Muntins:  Applied.
  356.         8.  Muntins:  Integral.
  357. NOTE ** Delete one of two paragraphs below.  Consult
  358.         manufacturer's product data for available colors.
  359.         9.  Color:  ________.
  360.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  361.             this section.
  362. NOTE ** Delete one of two paragraphs below.
  363.         11. Styles and Sizes:  Indicated on Drawings.
  364.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  365.             PART 3 of this section.
  366.  
  367.     B.  Acceptable Product:  New Castle Twin Single-Hung and
  368.         Triple Single-Hung; combined single-hung units.
  369. NOTE ** Consult manufacturer's product data for performance
  370.         of window styles; coordinate with window
  371.         selections.
  372.         1.  Unit performance when tested in accordance with AAMA
  373.             101:
  374.             a.  Air Infiltration:  ____ cubic feet per minute (__
  375.                 cu m/hr).
  376.             b.  Water Penetration: ____ cubic feet per minute (__
  377.                 cu m/hr).
  378.             c.  Structural Performance:  ____ pounds per square
  379.                 foot (__ kPa).
  380.             d.  Overall Rating:  Grade __.
  381.             e.  Operating Force:  ____ pounds (__ kg).
  382.         2.  Frame and Sash Construction:  Common frame and
  383.             integral reinforced jamb/mullion system for improved
  384.             structural performance and trimmer lines; mitered and
  385.             fusion-welded corners; integral 1 inch (25.4 mm) pre-
  386.             punched nailing fin four sides; integral weep system;
  387.             tilt-in lower sash interlocking to stay bar, with
  388.             surface-mounted tilt latches and molded-in lift rail;
  389.             one operable lower sash, one upper fixed sash.
  390.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  391.         4.  Operating Hardware:
  392.             a.  Locks:  Cam-type sash lock and keeper meeting
  393.                 forced entry resistance requirements of CAWM 301,
  394.                 engineered to force meeting rails together, for
  395.                 minimum air infiltration.
  396.             b.  Balances:  Stainless steel constant-force spring
  397.                 balances, 3/4 inch (19 mm) wide, meeting AAMA
  398.                 902, providing maintenance free operation without
  399.                 post-installation adjustment or lubrication.
  400.         5.  Weatherstripping:  Double-row high-density silicone-
  401.             treated polypropylene pile, with double mylar fin,
  402.             meeting AAMA 701; compression-type bulb seal at lower
  403.             rail meeting sill.
  404.         6.  Screens:  Frame color matching window frame and sash
  405.             interior color.
  406. NOTE ** Retain one or delete both paragraphs below for
  407.         specified window units.
  408.         7.  Muntins:  Applied.
  409.         8.  Muntins:  Integral.
  410. NOTE ** Delete one of two paragraphs below.  Consult
  411.         manufacturer's product data for available colors.
  412.         9.  Color:  ________.
  413.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  414.             this section.
  415. NOTE ** Delete one of two paragraphs below.
  416.         11. Styles and Sizes:  Indicated on Drawings.
  417.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  418.             PART 3 of this section.
  419.  
  420. 2.4 DOUBLE-HUNG WINDOWS
  421.  
  422.     A.  Acceptable Product:  New Castle XT Double-Hung.
  423. NOTE ** Consult manufacturer's product data for performance
  424.         of window styles; coordinate with window
  425.         selections.
  426.         1.  Unit performance when tested in accordance with AAMA
  427.             101:
  428.             a.  Air Infiltration:  ____ cubic feet per minute (__
  429.                 cu m/hr).
  430.             b.  Water Penetration:  ____ pounds per square foot
  431.                 (__ kPa) pressure before water leakage.
  432.             c.  Structural Performance:  ____ pounds per square
  433.                 foot (__ kPa).
  434.             d.  Overall Rating:  Grade __.
  435.             e.  Operating Force:  ____ pounds (__ kg).
  436.         2.  Frame and Sash Construction:  Mitered and fusion-
  437.             welded corners, with molded-in receptor pockets for
  438.             interior and exterior trim; welded sloped sill with 1
  439.             inch (25.4 mm) high welded sill dam; 1 inch (25.4 mm)
  440.             pre-punched nailing fin four sides; integral weep
  441.             system; tilt-in upper and lower sash with recess-
  442.             mounted tilt latches; integral glazing provision for
  443.             exterior glazing bead; lower sash with molded-in lift
  444.             rail; operable lower and upper sash.
  445.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  446.         4.  Operating Hardware:
  447.             a.  Locks:  Cam-type sash lock and keeper, engineered
  448.                 to force meeting rails together to minimize air
  449.                 infiltration.
  450.             b.  Balances:  Stainless steel constant-force spring
  451.                 balances, 3/4 inch (19 mm) wide, meeting AAMA
  452.                 902, providing maintenance free operation without
  453.                 post-installation adjustment or lubrication.
  454.         5.  Weatherstripping:  Double-row high-density silicone-
  455.             treated polypropylene pile, with double mylar fin,
  456.             meeting AAMA 701; compression-type bulb seal at lower
  457.             rail meeting sill.
  458.         6.  Screens:  Frame color matching window frame and sash
  459.             interior color.
  460. NOTE ** Retain one or delete both paragraphs below for
  461.         specified window units.
  462.         7.  Muntins:  Applied.
  463.         8.  Muntins:  Integral.
  464. NOTE ** Delete one of two paragraphs below.  Consult
  465.         manufacturer's product data for available colors.
  466.         9.  Color:  ________.
  467.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  468.             this section.
  469. NOTE ** Delete one of two paragraphs below.
  470.         11. Styles and Sizes:  Indicated on Drawings.
  471.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  472.             PART 3 of this section.
  473.  
  474. 2.5 HORIZONTAL GLIDING WINDOWS
  475. NOTE ** The following paragraph specifies New Castle Glider
  476.         window with single operable sash; delete if not
  477.         required.
  478.  
  479.     A.  Acceptable Product:  New Castle Glider.
  480. NOTE ** Consult manufacturer's product data for performance
  481.         of window styles; coordinate with window
  482.         selections.
  483.         1.  Unit performance when tested in accordance with AAMA
  484.             101:
  485.             a.  Air Infiltration:  ____ cubic feet per minute (__
  486.                 cu m/hr).
  487.             b.  Water Penetration:  ____ pounds per square foot
  488.                 (__ kPa) pressure before water leakage.
  489.             c.  Structural Performance:  ____ pounds per square
  490.                 foot (__ kPa).
  491.             d.  Overall Rating:  Grade __.
  492.             e.  Operating Force:  ____ pounds (__ kg).
  493.         2.  Frame and Sash Construction:  Mitered and fusion-
  494.             welded corners; integral 1 inch (25.4 mm) pre-punched
  495.             nailing fin four sides; integral weep system;
  496.             integral glazing provision; molded-in glide rail;
  497.             operable sash interlocks to the staybar; one operable
  498.             sash, one fixed sash.
  499.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  500.         4.  Operating Hardware:
  501.             a.  Locks:  Cam-type sash lock and keeper meeting
  502.                 forced entry resistance requirements of CAWM 301,
  503.                 engineered to force meeting stiles/rails, with
  504.                 interlock for minimum air infiltration.
  505. NOTE ** Delete one of two paragraphs below.
  506.             b.  Glides:  Glide pads on track.
  507.             c.  Glides:  Glide rollers on track.
  508.         5.  Weatherstripping:  Double-row high-density silicone-
  509.             treated polypropylene pile, with double mylar fin,
  510.             meeting AAMA 701.
  511.         6.  Screens:  Frame color matching window frame and sash
  512.             interior color.
  513. NOTE ** Retain one or delete both paragraphs below for
  514.         specified window units.
  515.         7.  Muntins:  Applied.
  516.         8.  Muntins:  Integral.
  517. NOTE ** Delete one of two paragraphs below.  Consult
  518.         manufacturer's product data for available colors.
  519.         9.  Color:  ________.
  520.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  521.             this section.
  522. NOTE ** Delete one of two paragraphs below.
  523.         11. Styles and Sizes:  Indicated on Drawings.
  524.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  525.             PART 3 of this section.
  526. NOTE ** The following paragraph specifies New Castle XT
  527.         Glider window with both sashes operable; delete if
  528.         not required.
  529.  
  530.     B.  Acceptable Product:  New Castle XT Glider.
  531. NOTE ** Consult manufacturer's product data for performance
  532.         of window styles; coordinate with window
  533.         selections.
  534.         1.  Unit performance when tested in accordance with AAMA
  535.             101:
  536.             a.  Air Infiltration:  ____ cubic feet per minute (__
  537.                 cu m/hr).
  538.             b.  Water Penetration:  ____ pounds per square foot
  539.                 (__ kPa) pressure before water leakage.
  540.             c.  Structural Performance:  ____ pounds per square
  541.                 foot (__ kPa).
  542.             d.  Overall Rating:  Grade __.
  543.             e.  Operating Force:  ____ pounds (__ kg).
  544.         2.  Frame and Sash Construction:  Mitered and fusion-
  545.             welded corners, with molded-in receptor pockets for
  546.             interior and exterior trim; integral 1 inch (25.4 mm)
  547.             pre-punched nailing fin four sides; independent weep
  548.             system for interior and exterior glide tracks;
  549.             integral glazing provision for exterior glazing bead;
  550.             molded-in glide rail; both sashes operable; sashes
  551.             lifting out for cleaning from inside; sashes non-
  552.             removable from outside.
  553.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  554.         4.  Operating Hardware:
  555.             a.  Locks:  Cam-type sash lock and keeper, engineered
  556.                 to force meeting rails together to minimize air
  557.                 infiltration.
  558. NOTE ** Delete one of two paragraphs below.
  559.             b.  Glides:  Glide pads on track.
  560.             c.  Glides:  Glide rollers on track.
  561.         5.  Weatherstripping:  Double-row high-density silicone-
  562.             treated polypropylene pile, with double mylar fin,
  563.             meeting AAMA 701.
  564.         6.  Screens:  Frame color matching window frame and sash
  565.             interior color.
  566. NOTE ** Retain one or delete both paragraphs below for
  567.         specified window units.
  568.         7.  Muntins:  Applied.
  569.         8.  Muntins:  Integral.
  570. NOTE ** Delete one of two paragraphs below.  Consult
  571.         manufacturer's product data for available colors.
  572.         9.  Color:  ________.
  573.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  574.             this section.
  575. NOTE ** Delete one of two paragraphs below.
  576.         11. Styles and Sizes:  Indicated on Drawings.
  577.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  578.             PART 3 of this section.
  579.  
  580. 2.6 CASEMENT WINDOWS
  581.  
  582.     A.  Acceptable Product:  New Castle Casement.
  583. NOTE ** Consult manufacturer's product data for performance
  584.         of window styles; coordinate with window
  585.         selections.
  586.         1.  Unit performance when tested in accordance with AAMA
  587.             101:
  588.             a.  Air Infiltration:  ____ cubic feet per minute (__
  589.                 cu m/hr).
  590.             b.  Water Penetration:  ____ pounds per square foot
  591.                 (__ kPa) pressure before water leakage.
  592.             c.  Structural Performance:  ____ pounds per square
  593.                 foot (__ kPa).
  594.             d.  Overall Rating:  Grade __.
  595.             e.  Operating Force:  ____ pounds (__ kg).
  596.         2.  Frame and Sash Construction:  Mitered and fusion-
  597.             welded corners; integral 1 inch (25.4 mm) pre-punched
  598.             nailing fin four sides; integral weep system;
  599.             integral glazing provision.
  600.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  601.         4.  Operating Hardware:
  602.             a.  Operator:  Gear-actuated rotary operator and
  603.                 handle.
  604.             b.  Locks:  Single-lever actuated, with multiple
  605.                 locking points, meeting forced entry resistance
  606.                 requirements of CAWM 301.
  607.         5.  Weatherstripping:  Double-row low-compression set
  608.             bulb gaskets.
  609.         6.  Screens:  Frame color matching window frame and sash
  610.             interior color.
  611. NOTE ** Retain one or delete both paragraphs below for
  612.         specified window units.
  613.         7.  Muntins:  Applied.
  614.         8.  Muntins:  Integral.
  615. NOTE ** Delete one of two paragraphs below.  Consult
  616.         manufacturer's product data for available colors.
  617.         9.  Color:  ________.
  618.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  619.             this section.
  620. NOTE ** Delete one of two paragraphs below.
  621.         11. Styles and Sizes:  Indicated on Drawings.
  622.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  623.             PART 3 of this section.
  624.  
  625. 2.7 AWNING WINDOWS
  626.  
  627.     A.  Acceptable Product:  New Castle Awning.
  628. NOTE ** Consult manufacturer's product data for performance
  629.         of window styles; coordinate with window
  630.         selections.
  631.         1.  Unit performance when tested in accordance with AAMA
  632.             101:
  633.             a.  Air Infiltration:  ____ cubic feet per minute (__
  634.                 cu m/hr).
  635.             b.  Water Penetration:  ____ pounds per square foot
  636.                 (__ kPa) pressure before water leakage.
  637.             c.  Structural Performance:  ____ pounds per square
  638.                 foot (__ kPa).
  639.             d.  Overall Rating:  Grade __.
  640.             e.  Operating Force:  ____ pounds (__ kg).
  641.         2.  Frame and Sash Construction:  Mitered and fusion-
  642.             welded corners; integral 1 inch (25.4 mm) pre-punched
  643.             nailing fin four sides; integral weep system;
  644.             integral glazing provision.
  645.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  646.         4.  Operating Hardware:
  647.             a.  Operator:  Gear-actuated rotary operator and
  648.                 handle.
  649.             b.  Locks:  Single-lever actuated, meeting forced
  650.                 entry resistance requirements of CAWM 301, with
  651.                 multiple locking points.
  652.         5.  Weatherstripping:  Double-row low-compression set
  653.             bulb gaskets.
  654.         6.  Screens:  Frame color matching window frame and sash
  655.             interior color.
  656. NOTE ** Retain one or delete both paragraphs below for
  657.         specified window units.
  658.         7.  Muntins:  Applied.
  659.         8.  Muntins:  Integral.
  660. NOTE ** Delete one of two paragraphs below.  Consult
  661.         manufacturer's product data for available colors.
  662.         9.  Color:  ________.
  663.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  664.             this section.
  665. NOTE ** Delete one of two paragraphs below.
  666.         11. Styles and Sizes:  Indicated on Drawings.
  667.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  668.             PART 3 of this section.
  669.  
  670. 2.8 BOW WINDOWS
  671.  
  672.     A.  Acceptable Product:  New Castle Casement Bow.
  673.         1.  Operable-sash Windows:
  674. NOTE ** Consult manufacturer's product data for performance
  675.         of window styles; coordinate with window
  676.         selections.
  677.             a.  Unit performance when tested in accordance with
  678.                 AAMA 101:
  679.                 1)  Air Infiltration:  ____ cubic feet per minute
  680.                     (__ cu m/hr).
  681.                 2)  Water Penetration:  ____ pounds per square
  682.                     foot (__ kPa) pressure before water leakage.
  683.                 3)  Structural Performance:  ____ pounds per
  684.                     square foot (__ kPa).
  685.                 4)  Overall Rating:  Grade __.
  686.                 5)  Operating Force:  ____ pounds (__ kg).
  687.             b.  Frame and Sash Construction:  Mitered and fusion-
  688.                 welded corners; integral 1 inch (25 mm) pre-
  689.                 punched nailing fin; integral weep system;
  690.                 integral glazing provision.
  691.             c.  Factory Glazing:  Insulating Glass Unit, Type
  692.                 ___.
  693.             d.  Operating Hardware:
  694.                 1)  Operator:  Gear-actuated rotary operator and
  695.                     handle.
  696.                 2)  Locks:  Single-lever actuated, meeting forced
  697.                     entry resistance requirements of CAWM 301,
  698.                     with multiple locking points.
  699.             e.  Weatherstripping:  Double-row low-compression set
  700.                 bulb gaskets.
  701.             f.  Screens:  Frame color matching window frame and
  702.                 sash interior color.
  703. NOTE ** Retain one or delete both paragraphs below for
  704.         specified window units.
  705.             g.  Muntins:  Applied.
  706.             h.  Muntins:  Integral.
  707.         2.  Fixed-Sash Windows:
  708. NOTE ** Consult manufacturer's product data for performance
  709.         of window styles; coordinate with window
  710.         selections.
  711.             a.  Unit performance when tested in accordance with
  712.                 AAMA 101:
  713.                 1)  Air Infiltration:  ____ cubic feet per minute
  714.                     (__ cu m/hr).
  715.                 2)  Water Penetration:  ____ pounds per square
  716.                     foot (__ kPa) pressure before water leakage.
  717.                 3)  Structural Performance:  ____ pounds per
  718.                     square foot (__ kPa).
  719.                 4)  Overall Rating:  Grade __.
  720.             b.  Frame:  Construction and profile matching
  721.                 operable-sash units; insulating glazing unit
  722.                 secured in integral glazing provision in frame.
  723.             c.  Factory Glazing:  Insulating Glass Unit, Type
  724.                 ___.
  725. NOTE ** Retain one or delete both paragraphs below for
  726.         specified window units.
  727.             d.  Muntins:  Applied.
  728.             e.  Muntins:  Integral.
  729. NOTE ** Delete one of two paragraphs below.  Consult
  730.         manufacturer's product data for available colors.
  731.         3.  Color:  ________.
  732.         4.  Color:  Indicated in SCHEDULES Article in PART 3 of
  733.             this section.
  734. NOTE ** Delete one of two paragraphs below.
  735.         5.  Styles and Sizes:  Indicated on Drawings.
  736.         6.  Styles and Sizes:  Indicated in SCHEDULES Article in
  737.             PART 3 of this section.
  738.  
  739.     B.  Installation Hardware:  Threaded-rod mullion support
  740.         system, adjustable.
  741.  
  742.     C.  Headboard and Seatboard:  Birch, vinyl-backed, insulated.
  743.  
  744. 2.9 BAY WINDOWS
  745. NOTE ** The following paragraph specifies New Castle Bay
  746.         window with fixed center window and single-hung
  747.         flanker windows; delete if not required.
  748.  
  749.     A.  Acceptable Product:  New Castle Bay; Fixed Center, Single-
  750.         Hung Flankers.
  751.         1.  Fixed Center Window:
  752. NOTE ** Consult manufacturer's product data for performance
  753.         of window styles; coordinate with window
  754.         selections.
  755.             a.  Unit performance when tested in accordance with
  756.                 AAMA 101:
  757.                 1)  Air Infiltration:  ____ cubic feet per minute
  758.                     (__ cu m/hr).
  759.                 2)  Water Penetration:  ____ pounds per square
  760.                     foot (__ kPa) pressure before water leakage.
  761.                 3)  Structural Performance:  ____ pounds per
  762.                     square foot (__ kPa).
  763.                 4)  Overall Rating:  Grade __.
  764.             b.  Frame Construction:  Mitered and fusion-welded
  765.                 corners; integral weep system; insulating glazing
  766.                 unit secured in integral glazing provision in
  767.                 frame.
  768.             c.  Factory Glazing:  Insulating Glass Unit, Type
  769.                 ___.
  770. NOTE ** Retain one or delete both paragraphs below for
  771.         specified window units.
  772.             d.  Muntins:  Applied.
  773.             e.  Muntins:  Integral.
  774.         2.  Single-Hung Flanker Windows:
  775. NOTE ** Consult manufacturer's product data for performance
  776.         of window styles; coordinate with window
  777.         selections.
  778.             a.  Unit performance when tested in accordance with
  779.                 AAMA 101:
  780.                 1)  Air Infiltration:  ____ cubic feet per minute
  781.                     (__ cu m/hr).
  782.                 2)  Water Penetration:  ____ pounds per square
  783.                     foot (__ kPa) pressure before water leakage.
  784.                 3)  Structural Performance:  ____ pounds per
  785.                     square foot (__ kPa).
  786.                 4)  Overall Rating:  Grade __.
  787.                 5)  Operating Force:  ____ pounds (__ kg).
  788. NOTE ** Delete one of two paragraphs below.
  789.             b.  Projection:  30 degrees from wall plane.
  790.             c.  Projection:  45 degrees from wall plane.
  791.             d.  Frame and Sash Construction:  Mitered and fusion-
  792.                 welded corners; integral 1 inch (25.4 mm) pre-
  793.                 punched nailing fin; integral weep system; tilt-
  794.                 in lower sash with integral lift rails; integral
  795.                 glazing provision; lower sash interlocks to the
  796.                 stay bar; one operable lower sash, one upper
  797.                 fixed sash.
  798.             e.  Factory Glazing:  Insulating Glass Unit, Type
  799.                 ___.
  800.             f.  Operating Hardware:
  801.                 1)  Locks:  Cam-type sash lock and keeper meeting
  802.                     forced entry resistance requirements of CAWM
  803.                     301, engineered to force meeting rails
  804.                     together to minimize air infiltration.
  805.                 2)  Balances:  Stainless steel constant-force
  806.                     spring balances, 3/4 inch (19 mm) wide,
  807.                     meeting AAMA 902, providing maintenance free
  808.                     operation without post-installation
  809.                     adjustment or lubrication.
  810.             g.  Weatherstripping:  Double-row high-density
  811.                 silicone-treated polypropylene pile, with double
  812.                 mylar fin, meeting AAMA 701; compression-type
  813.                 bulb seal at lower rail meeting sill.
  814.             h.  Screens:  Frame color matching window frame and
  815.                 sash interior color.
  816. NOTE ** Retain one or delete both paragraphs below for
  817.         specified window units.
  818.             i.  Muntins:  Applied.
  819.             j.  Muntins:  Integral.
  820. NOTE ** Delete one of two paragraphs below.  Consult
  821.         manufacturer's product data for available colors.
  822.         3.  Color:  ________.
  823.         4.  Color:  Indicated in SCHEDULES Article in PART 3 of
  824.             this section.
  825. NOTE ** Delete one of two paragraphs below.
  826.         5.  Styles and Sizes:  Indicated on Drawings.
  827.         6.  Styles and Sizes:  Indicated in SCHEDULES Article in
  828.             PART 3 of this section.
  829. NOTE ** The following paragraph specifies New Castle Bay
  830.         window with fixed center window and casement
  831.         flanker windows; delete if not required.
  832.  
  833.     B.  Acceptable Product:  New Castle Bay; Fixed Center,
  834.         Casement Flankers.
  835.         1.  Fixed Center Window:
  836. NOTE ** Consult manufacturer's product data for performance
  837.         of window styles; coordinate with window
  838.         selections.
  839.             a.  Unit performance when tested in accordance with
  840.                 AAMA 101:
  841.                 1)  Air Infiltration:  ____ cubic feet per minute
  842.                     (__ cu m/hr).
  843.                 2)  Water Penetration:  ____ pounds per square
  844.                     foot (__ kPa) pressure before water leakage.
  845.                 3)  Structural Performance:  ____ pounds per
  846.                     square foot (__ kPa).
  847.                 4)  Overall Rating:  Grade __.
  848.             b.  Frame Construction:  Mitered and fusion-welded
  849.                 corners; integral weep system; insulating glazing
  850.                 unit secured in integral glazing provision in
  851.                 frame.
  852.             c.  Factory Glazing:  Insulating Glass Unit, Type
  853.                 ___.
  854. NOTE ** Retain one or delete both paragraphs below for
  855.         specified window units.
  856.             d.  Muntins:  Applied.
  857.             e.  Muntins:  Integral.
  858.         2.  Casement Flanker Windows:
  859. NOTE ** Consult manufacturer's product data for performance
  860.         of window styles; coordinate with window
  861.         selections.
  862.             a.  Unit performance when tested in accordance with
  863.                 AAMA 101:
  864.                 1)  Air Infiltration:  ____ cubic feet per minute
  865.                     (__ cu m/hr).
  866.                 2)  Water Penetration:  ____ pounds per square
  867.                     foot (__ kPa) pressure before water leakage.
  868.                 3)  Structural Performance:  ____ pounds per
  869.                     square foot (__ kPa).
  870.                 4)  Overall Rating:  Grade __.
  871.                 5)  Operating Force:  ____ pounds (__ kg).
  872. NOTE ** Delete one of two paragraphs below.
  873.             b.  Projection:  30 degrees from wall plane.
  874.             c.  Projection:  45 degrees from wall plane.
  875.             d.  Frame and Sash Construction:  Mitered and fusion-
  876.                 welded corners; integral 1 inch (25.4 mm) pre-
  877.                 punched nailing fin; integral weep system;
  878.                 integral glazing provision.
  879.             e.  Factory Glazing:  Insulating Glass Unit, Type
  880.                 ___.
  881.             f.  Operating Hardware:
  882.                 1)  Operator:  Gear-actuated rotary operator and
  883.                     handle.
  884.                 2)  Locks:  Single-lever actuated, with multiple
  885.                     locking points, meeting forced entry
  886.                     resistance requirements of CAWM 301.
  887.             g.  Weatherstripping:  Double-row low-compression set
  888.                 bulb gaskets.
  889.             h.  Screens:  Frame color matching window frame and
  890.                 sash interior color.
  891. NOTE ** Retain one or delete both paragraphs below for
  892.         specified window units.
  893.             i.  Muntins:  Applied.
  894.             j.  Muntins:  Integral.
  895. NOTE ** Delete one of two paragraphs below.  Consult
  896.         manufacturer's product data for available colors.
  897.         3.  Color:  ________.
  898.         4.  Color:  Indicated in SCHEDULES Article in PART 3 of
  899.             this section.
  900. NOTE ** Delete one of two paragraphs below.
  901.         5.  Styles and Sizes:  Indicated on Drawings.
  902.         6.  Styles and Sizes:  Indicated in SCHEDULES Article in
  903.             PART 3 of this section.
  904. NOTE ** The following paragraph specifies New Castle XT Bay
  905.         window with fixed center window and double-hung
  906.         flanker windows; delete if not required.
  907.  
  908.     C.  Acceptable Product:  New Castle XT Bay; Fixed Center,
  909.         Double-Hung Flankers.
  910.         1.  Fixed Center Window:
  911. NOTE ** Consult manufacturer's product data for performance
  912.         of window styles; coordinate with window
  913.         selections.
  914.             a.  Unit performance when tested in accordance with
  915.                 AAMA 101:
  916.                 1)  Air Infiltration:  ____ cubic feet per minute
  917.                     (__ cu m/hr).
  918.                 2)  Water Penetration:  ____ pounds per square
  919.                     foot (__ kPa) pressure before water leakage.
  920.                 3)  Structural Performance:  ____ pounds per
  921.                     square foot (__ kPa).
  922.                 4)  Overall Rating:  Grade __.
  923.             b.  Frame Construction:  Mitered and fusion-welded
  924.                 corners with molded-in receptor pockets for
  925.                 interior an exterior trim; 1 inch (25 mm) pre-
  926.                 punched nailing fin; integral weep system;
  927.                 insulating glazing unit secured in integral
  928.                 glazing provision in frame.
  929.             c.  Factory Glazing:  Insulating Glass Unit, Type
  930.                 ___.
  931. NOTE ** Retain one or delete both paragraphs below for
  932.         specified window units.
  933.             d.  Muntins:  Applied.
  934.             e.  Muntins:  Integral.
  935.         2.  Double-Hung Flanker Windows:
  936. NOTE ** Consult manufacturer's product data for performance
  937.         of window styles; coordinate with window
  938.         selections.
  939.             a.  Unit performance when tested in accordance with
  940.                 AAMA 101:
  941.                 1)  Air Infiltration:  ____ cubic feet per minute
  942.                     (__ cu m/hr).
  943.                 2)  Water Penetration:  ____ pounds per square
  944.                     foot (__ kPa) pressure before water leakage.
  945.                 3)  Structural Performance:  ____ pounds per
  946.                     square foot (__ kPa).
  947.                 4)  Overall Rating:  Grade __.
  948.                 5)  Operating Force:  ____ pounds (__ kg).
  949. NOTE ** Delete one of two paragraphs below.
  950.             b.  Projection:  30 degrees from wall plane.
  951.             c.  Projection:  45 degrees from wall plane.
  952.             d.  Frame and Sash Construction:  Mitered and fusion-
  953.                 welded corners, with molded-in receptor pockets
  954.                 for interior and exterior trim; welded sloped
  955.                 sill with 1 inch (25.4 mm) high welded sill dam;
  956.                 1 inch (25.4 mm) pre-punched nailing fin;
  957.                 integral weep system; tilt-in upper and lower
  958.                 sash with recess-mounted tilt latches; integral
  959.                 glazing provision for exterior glazing bead;
  960.                 lower sash with molded-in lift rail; operable
  961.                 lower and upper sash.
  962.             e.  Factory Glazing:  Insulating Glass Unit, Type
  963.                 ___.
  964.             f.  Operating Hardware:
  965.                 1)  Locks:  Cam-type sash lock and keeper,
  966.                     engineered to force meeting rails together to
  967.                     minimize air infiltration.
  968.                 2)  Balances:  Stainless steel constant-force
  969.                     spring balances, 3/4 inch (19 mm) wide,
  970.                     meeting AAMA 902, providing maintenance free
  971.                     operation without post-installation
  972.                     adjustment or lubrication.
  973.             g.  Weatherstripping:  Double-row high-density
  974.                 silicone-treated polypropylene pile, with double
  975.                 mylar fin, meeting AAMA 701; compression-type
  976.                 bulb seal at lower rail meeting sill.
  977.             h.  Screens:  Frame color matching window frame and
  978.                 sash interior color.
  979. NOTE ** Retain one or delete both paragraphs below for
  980.         specified window units.
  981.             i.  Muntins:  Applied.
  982.             j.  Muntins:  Integral.
  983. NOTE ** Delete one of two paragraphs below.  Consult
  984.         manufacturer's product data for available colors.
  985.         3.  Color:  ________.
  986.         4.  Color:  Indicated in SCHEDULES Article in PART 3 of
  987.             this section.
  988. NOTE ** Delete one of two paragraphs below.
  989.         5.  Styles and Sizes:  Indicated on Drawings.
  990.         6.  Styles and Sizes:  Indicated in SCHEDULES Article in
  991.             PART 3 of this section.
  992.  
  993.     D.  Installation Hardware:  Threaded-rod mullion support
  994.         system, adjustable.
  995.  
  996.     E.  Headboard and Seatboard:  Birch, vinyl-backed, insulated.
  997.  
  998. 2.10    OPERABLE EXTENDED ARCH WINDOWS
  999.  
  1000.     A.  Acceptable Product:  New Castle Operable Extended Arch.
  1001. NOTE ** Consult manufacturer's product data for performance
  1002.         of window styles; coordinate with window
  1003.         selections.
  1004.         1.  Unit performance when tested in accordance with AAMA
  1005.             101:
  1006.             a.  Air Infiltration:  ____ cubic feet per minute (__
  1007.                 cu m/hr).
  1008.             b.  Water Penetration:  ____ pounds per square foot
  1009.                 (__ kPa) pressure before water leakage.
  1010.             c.  Structural Performance:  ____ pounds per square
  1011.                 foot (__ kPa).
  1012.             d.  Overall Rating:  Grade __.
  1013.             e.  Operating Force:  ____ pounds (__ kg).
  1014.         2.  Frame and Sash Construction:  Mitered and fusion-
  1015.             welded corners; integral 1 inch (25.4 mm) pre-punched
  1016.             nailing fin four sides; integral weep system; tilt-in
  1017.             lower sash with surface-mounted tilt latches;
  1018.             integral glazing provision; lower sash with molded-in
  1019.             lift rail; one operable lower sash, one upper fixed
  1020.             sash.
  1021.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  1022.         4.  Operating Hardware:
  1023.             a.  Locks:  Cam-type sash lock and keeper meeting
  1024.                 forced entry resistance requirements of CAWM 301,
  1025.                 engineered to force meeting rails together to
  1026.                 minimize air infiltration.
  1027.             b.  Balances:  Stainless steel constant-force spring
  1028.                 balances, 3/4 inch (19 mm) wide, meeting AAMA
  1029.                 902, providing maintenance free operation without
  1030.                 post-installation adjustment or lubrication.
  1031.         5.  Weatherstripping:  Double-row high-density silicone-
  1032.             treated polypropylene pile, with double mylar fin,
  1033.             meeting AAMA 701; compression-type bulb seal at lower
  1034.             rail meeting sill.
  1035.         6.  Screens:  Frame color matching window frame and sash
  1036.             interior color.
  1037. NOTE ** Retain one or delete both paragraphs below for
  1038.         specified window units.
  1039.         7.  Muntins:  Applied.
  1040.         8.  Muntins:  Integral.
  1041. NOTE ** Delete one of two paragraphs below.  Consult
  1042.         manufacturer's product data for available colors.
  1043.         9.  Color:  ________.
  1044.         10. Color:  Indicated in SCHEDULES Article in PART 3 of
  1045.             this section.
  1046. NOTE ** Delete one of two paragraphs below.
  1047.         11. Styles and Sizes:  Indicated on Drawings.
  1048.         12. Styles and Sizes:  Indicated in SCHEDULES Article in
  1049.             PART 3 of this section.
  1050.  
  1051. 2.11    FIXED GEOMETRIC WINDOWS
  1052. NOTE ** New Castle Architectural Shape(tm) windows include
  1053.         a variety of shapes and associated muntin designs
  1054.         and have a frame design which compliments other New
  1055.         Castle window styles.  Consult manufacturer's
  1056.         product literature for available options.
  1057. NOTE **
  1058. NOTE ** The principal differences between the New Castle
  1059.         and New Castle XT Architectural Shape windows are
  1060.         the frame profile and the glazing thickness:  New
  1061.         Castle has 5/8 inch glazing, while New Castle XT
  1062.         has 7/8 inch glazing.
  1063.  
  1064.     A.  Acceptable Product:  New Castle Architectural Shape
  1065.         Windows, Style _________.
  1066. NOTE ** Consult manufacturer's product data for performance
  1067.         of window styles; coordinate with window
  1068.         selections.
  1069.         1.  Unit performance when tested in accordance with AAMA
  1070.             101:
  1071.             a.  Air Infiltration:  ____ cubic feet per minute (__
  1072.                 cu m/hr).
  1073.             b.  Water Penetration:  ____ pounds per square foot
  1074.                 (__ kPa) pressure before water leakage.
  1075.             c.  Structural Performance:  ____ pounds per square
  1076.                 foot (__ kPa).
  1077.             d.  Overall Rating:  Grade __.
  1078.         2.  Frame Construction:  Mitered and fusion-welded
  1079.             corners; integral weep system; insulating glazing
  1080.             unit secured in integral glazing provision in frame.
  1081.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  1082. NOTE ** Retain one or delete both paragraphs below for
  1083.         specified window units.
  1084.         4.  Muntins:  Applied.
  1085.         5.  Muntins:  Integral.
  1086. NOTE ** Delete one of two paragraphs below.  Consult
  1087.         manufacturer's product data for available colors.
  1088.         6.  Color:  ________.
  1089.         7.  Color:  Indicated in SCHEDULES Article in PART 3 of
  1090.             this section.
  1091. NOTE ** Delete one of two paragraphs below.
  1092.         8.  Styles, Patterns, and Sizes:  Indicated on Drawings.
  1093.         9.  Styles, Patterns, and Sizes:  Indicated in SCHEDULES
  1094.             Article in PART 3 of this section.
  1095. NOTE ** New Castle XT Architectural Shape(tm) windows
  1096.         include a variety of shapes and associated muntin
  1097.         designs and have a frame design which compliments
  1098.         other New Castle XT window styles.  Consult
  1099.         manufacturer's product literature for available
  1100.         options.
  1101.  
  1102.     B.  Acceptable Product:  New Castle XT Architectural Shape
  1103.         Windows, Style _________.
  1104. NOTE ** Consult manufacturer's product data for performance
  1105.         of window styles; coordinate with window
  1106.         selections.
  1107.         1.  Unit performance when tested in accordance with AAMA
  1108.             101:
  1109.             a.  Air Infiltration:  ____ cubic feet per minute (__
  1110.                 cu m/hr).
  1111.             b.  Water Penetration:  ____ pounds per square foot
  1112.                 (__ kPa) pressure before water leakage.
  1113.             c.  Structural Performance:  ____ pounds per square
  1114.                 foot (__ kPa).
  1115.             d.  Overall Rating:  Grade __.
  1116.         2.  Frame Construction:  Mitered and fusion-welded
  1117.             corners, with molded-in receptor pockets for interior
  1118.             and exterior trim; integral weep system; insulating
  1119.             glazing unit secured in integral glazing provision in
  1120.             frame; exterior glazing bead.
  1121.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  1122. NOTE ** Retain one or delete both paragraphs below for
  1123.         specified window units.
  1124.         4.  Muntins:  Applied.
  1125.         5.  Muntins:  Integral.
  1126. NOTE ** Delete one of two paragraphs below.  Consult
  1127.         manufacturer's product data for available colors.
  1128.         6.  Color:  ________.
  1129.         7.  Color:  Indicated in SCHEDULES Article in PART 3 of
  1130.             this section.
  1131. NOTE ** Delete one of two paragraphs below.
  1132.         8.  Styles, Patterns, and Sizes:  Indicated on Drawings.
  1133.         9.  Styles, Patterns, and Sizes:  Indicated in SCHEDULES
  1134.             Article in PART 3 of this section.
  1135.  
  1136. 2.12    FIXED WINDOWS AND TRANSOMS
  1137.  
  1138.     A.  Acceptable Product:  New Castle Fixed windows.
  1139. NOTE ** Consult manufacturer's product data for performance
  1140.         of window styles; coordinate with window
  1141.         selections.
  1142.         1.  Unit performance when tested in accordance with AAMA
  1143.             101:
  1144.             a.  Air Infiltration:  ____ cubic feet per minute (__
  1145.                 cu m/hr).
  1146.             b.  Water Penetration:  ____ pounds per square foot
  1147.                 (__ kPa) pressure before water leakage.
  1148.             c.  Structural Performance:  ____ pounds per square
  1149.                 foot (__ kPa).
  1150.             d.  Overall Rating:  Grade __.
  1151.         2.  Frame Construction:  Profile to complement New Castle
  1152.             Single Hung and Glider windows; mitered and fusion-
  1153.             welded corners; integral weep system; insulating
  1154.             glazing unit secured in integral glazing provision in
  1155.             frame.
  1156.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  1157. NOTE ** Retain one or delete both paragraphs below for
  1158.         specified window units.
  1159.         4.  Muntins:  Applied.
  1160.         5.  Muntins:  Integral.
  1161. NOTE ** Delete one of two paragraphs below.  Consult
  1162.         manufacturer's product data for available colors.
  1163.         6.  Color:  ________.
  1164.         7.  Color:  Indicated in SCHEDULES Article in PART 3 of
  1165.             this section.
  1166. NOTE ** Delete one of two paragraphs below.
  1167.         8.  Styles, Patterns, and Sizes:  Indicated on Drawings.
  1168.         9.  Styles, Patterns, and Sizes:  Indicated in SCHEDULES
  1169.             Article in PART 3 of this section.
  1170.  
  1171.     B.  Acceptable Product:  New Castle Casement Fixed windows.
  1172. NOTE ** Consult manufacturer's product data for performance
  1173.         of window styles; coordinate with window
  1174.         selections.
  1175.         1.  Unit performance when tested in accordance with AAMA
  1176.             101:
  1177.             a.  Air Infiltration:  ____ cubic feet per minute (__
  1178.                 cu m/hr).
  1179.             b.  Water Penetration:  ____ pounds per square foot
  1180.                 (__ kPa) pressure before water leakage.
  1181.             c.  Structural Performance:  ____ pounds per square
  1182.                 foot (__ kPa).
  1183.             d.  Overall Rating:  Grade __.
  1184.         2.  Frame Construction:  Profile to complement New Castle
  1185.             Casement windows; insulating glazing unit secured in
  1186.             integral glazing provision in frame.
  1187.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  1188. NOTE ** Retain one or delete both paragraphs below for
  1189.         specified window units.
  1190.         4.  Muntins:  Applied.
  1191.         5.  Muntins:  Integral.
  1192. NOTE ** Delete one of two paragraphs below.  Consult
  1193.         manufacturer's product data for available colors.
  1194.         6.  Color:  ________.
  1195.         7.  Color:  Indicated in SCHEDULES Article in PART 3 of
  1196.             this section.
  1197. NOTE ** Delete one of two paragraphs below.
  1198.         8.  Styles, Patterns, and Sizes:  Indicated on Drawings.
  1199.         9.  Styles, Patterns, and Sizes:  Indicated in SCHEDULES
  1200.             Article in PART 3 of this section.
  1201.  
  1202.  
  1203.     C.  Acceptable Product:  New Castle XT Fixed windows.
  1204. NOTE ** Consult manufacturer's product data for performance
  1205.         of window styles; coordinate with window
  1206.         selections.
  1207.         1.  Unit performance when tested in accordance with AAMA
  1208.             101:
  1209.             a.  Air Infiltration:  ____ cubic feet per minute (__
  1210.                 cu m/hr).
  1211.             b.  Water Penetration:  ____ pounds per square foot
  1212.                 (__ kPa) pressure before water leakage.
  1213.             c.  Structural Performance:  ____ pounds per square
  1214.                 foot (__ kPa).
  1215.             d.  Overall Rating:  Grade __.
  1216.         2.  Frame Construction:  Profile to complement New Castle
  1217.             XT Double Hung and Glider windows; mitered and fusion-
  1218.             welded corners with molded-in receptor pockets for
  1219.             interior and exterior trim; integral weep system;
  1220.             insulating glazing unit secured in integral glazing
  1221.             provision in frame.
  1222.         3.  Factory Glazing:  Insulating Glass Unit, Type ___.
  1223. NOTE ** Retain one or delete both paragraphs below for
  1224.         specified window units.
  1225.         4.  Muntins:  Applied.
  1226.         5.  Muntins:  Integral.
  1227. NOTE ** Delete one of two paragraphs below.  Consult
  1228.         manufacturer's product data for available colors.
  1229.         6.  Color:  ________.
  1230.         7.  Color:  Indicated in SCHEDULES Article in PART 3 of
  1231.             this section.
  1232. NOTE ** Delete one of two paragraphs below.
  1233.         8.  Styles, Patterns, and Sizes:  Indicated on Drawings.
  1234.         9.  Styles, Patterns, and Sizes:  Indicated in SCHEDULES
  1235.             Article in PART 3 of this section.
  1236.  
  1237. 2.13    PATIO DOORS
  1238.  
  1239.     A.  Acceptable Product:  New Castle Patio Door.
  1240. NOTE ** Consult manufacturer's product data for performance
  1241.         of window styles; coordinate with window
  1242.         selections.
  1243.         1.  Unit performance when tested in accordance with AAMA
  1244.             101:
  1245.             a.  Air Infiltration:  ____ cubic feet per minute (__
  1246.                 cu m/hr).
  1247.             b.  Water Penetration:  ____ pounds per square foot
  1248.                 (__ kPa) pressure before water leakage.
  1249.             c.  Structural Performance:  ____ pounds per square
  1250.                 foot (__ kPa).
  1251.             d.  Overall Rating:  Grade __.
  1252.             e.  Operating Force:  ____ pounds (__ kg).
  1253.         2.  Frame and Sash Construction:
  1254.             a.  Mitered and fusion-welded corners; integral 1
  1255.                 inch (25.4 mm) pre-punched nailing fin four
  1256.                 sides; integral weep system; integral glazing
  1257.                 provision.
  1258.             b.  Stiles:  Aluminum reinforced; interlocking
  1259.                 meeting stiles.
  1260.             c.  Fixed Units:  Frame profile matching operable
  1261.                 units; fixed insulating glazing unit secured in
  1262.                 integral glazing provision in frame.
  1263.         3.  Glazing:  Insulating Unit, thickness 7/8 inch (22.2
  1264.             mm):
  1265.             a.  Inner Pane:  Tempered 1/8 inch (3 mm) thick
  1266.                 glass, clear color.
  1267.             b.  Hermetically sealed air space between panes;
  1268.                 argon gas-filled, with low conductance spacer.
  1269.             c.  Outer Pane:  Tempered 1/8 inch (3 mm) thick
  1270.                 glass, clear color; manufacturer's proprietary
  1271.                 Thermaflect double sputter-coated high
  1272.                 performance low-emissivity coating on air-space
  1273.                 side.
  1274. NOTE ** Retain the preceding three sub-paragraphs, or the
  1275.         following three sub-paragraphs, to specify glazing
  1276.         required for project.
  1277.             d.  Outer Pane:  Tempered 1/8 inch (3 mm) thick
  1278.                 glass, clear color.
  1279.             e.  Hermetically sealed air space between panes, with
  1280.                 low conductance spacer.
  1281.             f.  Inner Pane:  Tempered 1/8 inch (3 mm) thick
  1282.                 glass, clear color.
  1283.         4.  Operating Hardware:
  1284.             a.  Roller Track:  Anodized aluminum, thermally
  1285.                 broken, with stainless steel cap.
  1286.             b.  Rollers:  Adjustable tandem stainless steel
  1287.                 rollers.
  1288.             c.  Stops:  Anti-lift, preventing operable sash to be
  1289.                 removed from exterior.
  1290. NOTE ** Retain one of the following three sub-paragraphs to
  1291.         specify lock type.
  1292.             d.  Locks:  Single-lever actuated two-point locking;
  1293.                 catch at locking points, meeting forced entry
  1294.                 resistance requirements of CAWM 301; lock key-
  1295.                 actuated from exterior; white baked enamel
  1296.                 handle.
  1297.             e.  Locks:  Single-lever actuated three-point
  1298.                 locking; steel rods through head and sill, catch
  1299.                 at locking point, meeting forced entry resistance
  1300.                 requirements of CAWM 301; lock key-actuated from
  1301.                 exterior; white baked enamel handle.
  1302.             f.  Locks:  Single-lever actuated three-point
  1303.                 locking; steel rods through head and sill, catch
  1304.                 at locking point, meeting forced entry resistance
  1305.                 requirements of CAWM 301; lock key-actuated from
  1306.                 exterior; European design with solid brass
  1307.                 handle.
  1308. NOTE ** Retain one or delete both paragraphs below for
  1309.         specified window units.
  1310.         5.  Muntins:  Applied.
  1311.         6.  Muntins:  Integral.
  1312. NOTE ** Delete one of two paragraphs below.  Consult
  1313.         manufacturer's product data for available colors.
  1314.         7.  Color:  ________.
  1315.         8.  Color:  Indicated in SCHEDULES Article in PART 3 of
  1316.             this section.
  1317.         9.  Weatherstripping:  Double-row high-density silicone-
  1318.             treated polypropylene pile, with double mylar fin,
  1319.             meeting AAMA 701.
  1320.         10. Screens:  Frame color matching window frame and sash
  1321.             interior color.
  1322.  
  1323. 2.14    GARDEN WINDOWS
  1324.  
  1325.     A.  Acceptable Product:  CertainTeed Garden Window.
  1326.         1.  Fixed Center and Overhead Window:
  1327.             a.  Frame:  Solid vinyl extrusions; mitered and
  1328.                 fusion-welded corners, with internal aluminum
  1329.                 frame support; integral weep system; insulating
  1330.                 glazing units secured in integral glazing
  1331.                 provision in frame.
  1332.             b.  Factory Glazing:  Insulating glass unit, 7/8 inch
  1333.                 (22.2 mm) unit thickness, with clear glass inner
  1334.                 pane, clear glass outer pane with Thermaflect(R)
  1335.                 double sputter-coated high performance coating on
  1336.                 air chamber side, argon gas-filled air chamber,
  1337.                 and low-conductance seal.
  1338.         2.  Casement Flanker Windows:
  1339.             a.  Sash:  Solid vinyl extrusions; mitered and fusion-
  1340.                 welded corners.
  1341.             b.  Factory Glazing:  Insulating glass unit, 7/8 inch
  1342.                 (22.2 mm) unit thickness, with clear glass inner
  1343.                 pane, clear glass outer pane with Thermaflect(R)
  1344.                 double sputter-coated high performance coating on
  1345.                 air chamber side, argon gas-filled air chamber,
  1346.                 and low-conductance seal.
  1347.             c.  Operating Hardware:
  1348.                 1)  Operator:  Gear-actuated rotary operator and
  1349.                     handle.
  1350.                 2)  Locks:  Single-lever actuated, with multiple
  1351.                     locking points, meeting forced entry
  1352.                     resistance requirements of CAWM 301.
  1353.             d.  Weatherstripping:  Double-row low-compression set
  1354.                 bulb gaskets.
  1355.             e.  Screens:  Frame color matching window frame and
  1356.                 sash interior color.
  1357.         3.  Seatboard:  Insulated, 2 inches (50 mm) thick, with
  1358.             birch interior capable of being field-finished.
  1359. NOTE ** Delete one of two paragraphs below.  Consult
  1360.         manufacturer's product data for available colors.
  1361.         4.  Color:  ________.
  1362.         5.  Color:  Indicated in SCHEDULES Article in PART 3 of
  1363.             this section.
  1364. NOTE ** Delete one of two paragraphs below.
  1365.         6.  Sizes:  Indicated on Drawings.
  1366.         7.  Sizes:  Indicated in SCHEDULES Article in PART 3 of
  1367.             this section.
  1368. NOTE ** The following is an option; delete paragraph if not
  1369.         required.
  1370.  
  1371.     B.  Shelf:  Clear tempered glass, on adjustable supports.
  1372. NOTE ** Delete paragraphs specifying accessories not
  1373.         required in the following Article; delete entire
  1374.         Article if no accessories required.
  1375.  
  1376. 2.15    ACCESSORIES
  1377. NOTE ** Delete one of the following two paragraphs if
  1378.         mullions are required.  The first is for New Castle
  1379.         windows, the second is for New Castle XT windows
  1380.         only.
  1381.  
  1382.     A.  Mullions:  Extruded rigid vinyl with concealed 16 gage
  1383.         galvanized steel or aluminum reinforcement; extruded
  1384.         rigid vinyl flashing clip; color to match adjacent window
  1385.         frames.
  1386.  
  1387.     B.  Mullions:  Structural mullion system complying with AAMA
  1388.         Grade deflection requirements for supported windows;
  1389.         extruded aluminum core; galvanized reinforcing strips if
  1390.         required; internal and external rigid PVC caps with
  1391.         compression gaskets; anchored to rough opening with
  1392.         reinforcement bracket; color to match adjacent window
  1393.         frames.
  1394. NOTE ** The following paragraph specifies snap-in trim
  1395.         accessories available for New Castle XT windows;
  1396.         delete entire paragraph if New Castle XT windows
  1397.         are not specified.  If paragraph is retained, edit
  1398.         listed items as applicable to project.
  1399.  
  1400. C.  Trim Accessories:  Extruded rigid polyvinyl chloride (PVC)
  1401.     shapes for snap-in fit in molded-in receptor pockets in
  1402.     window frame:
  1403.     1.  J-channel for exterior siding up to 1/2 inch (12.8 mm)
  1404.         thick.
  1405.     2.  J-channel for exterior siding up to 3/4 inch (19mm)
  1406.         thick.
  1407.     3.  Return for interior drywall up to 1/2 inch (12.8 mm)
  1408.         thick.
  1409.     4.  Return for interior wood trim up to 3/4 inch (19mm)
  1410.         thick.
  1411.  
  1412.  
  1413. PART 3  EXECUTION
  1414.  
  1415. 3.1 EXAMINATION
  1416.  
  1417.     A.  Have installer verify that project conditions are
  1418.         acceptable before beginning installation of products;
  1419.         verify that rough openings are as indicated, and are
  1420.         correct sizes for clearance spaces specified in
  1421.         manufacturer's instructions.
  1422.  
  1423.     B.  Correct unacceptable conditions before proceeding with
  1424.         installation.
  1425.  
  1426. 3.2 INSTALLATION
  1427.  
  1428.     A.  Install products in accordance manufacturer's
  1429.         instructions and approved shop drawings.
  1430.  
  1431.     B.  Install products plumb and in true alignment; fasten to
  1432.         achieve maximum operational effectiveness and appearance
  1433.         of units.
  1434.  
  1435. 3.3 ADJUSTING
  1436.  
  1437.     A.  Ensure that windows and doors operate correctly, free
  1438.         from binding or other defects.
  1439.  
  1440. 3.4 CLEANING
  1441.  
  1442.     A.  Clean and restore soiled surfaces; remove scraps and
  1443.         debris, and leave site in clean condition.
  1444.  
  1445. 3.5 SCHEDULE
  1446. NOTE ** Below are suggested schedule formats, if Schedule
  1447.         has been referenced in previous articles.  Consult
  1448.         manufacturer's product data for available colors
  1449.         and callout sizes.  Coordinate Style designations
  1450.         with drawings.
  1451.  
  1452.     A.  Window Schedule:
  1453.         1.  Window Style ___:
  1454.             a.  Style:  Casement-Fixed-Casement, with Transom.
  1455.             b.  Callout Size:  CFC5436.
  1456.             c.  Color:  Tan.
  1457.         2.  Window Style ___:
  1458.             a.  Style:  Geometric Half-Round, with Starburst
  1459.                 muntin pattern.
  1460.             b.  Callout Size:  HR6030.
  1461.             c.  Color:  Tan.
  1462.  
  1463.     B.  Patio Door Schedule:
  1464.         1.  Door Style ___:
  1465.             a.  Style:  OX, outside view.
  1466.             b.  Callout Size:  PD7280.
  1467.             c.  Color:  Tan.
  1468.  